P57 ASSESSMENT OF PULSE WAVE VELOCITY AND ASSOCIATION TO TARGET ORGAN DAMAGE IN TREATMENT-NAïVE HYPERTENSIVE PATIENTS: A COMPARISON OF SPHYGMOCOR AND MOBIL-O-GRAPH
- DOI
- 10.1016/j.artres.2017.10.079How to use a DOI?
- Abstract
- Introduction: Comparison of Mobil-O-Graph® with SphygmoCor® exclusively in treatment- naïve hypertensives has never been done. Aims of the study were to assess 1) intra- device agreement between both methods, 2) inter-device agreement between two surface measurements of SC (subtracted distance (cfPWVsub)) and direct distance × 0.8 (cfPWV0.8)) with two patient’s positions of MG (supine (supPWVestim)) and sitting (sitPWVestim)), 3) the strength of association between tonometric and oscillometric measures of PWV with target organ damage (TOD). - Methods: Cross-sectional, observational study in 171 consecutive, treatment-naïve subjects derived to a Hypertension Unit with suspected hypertension. Standard echocardiography, ECG, carotid ultrasound and laboratory tests were performed. - Results: Mean age was 49.7 years, 57.3% were women. Reproducibility: Mean differences (±SD of the difference (SDD)) between duplicate SC and MG PWV measurements were non-significant. Agreement: cfPWV0.8 yielded the highest PWV values (8.17±1.6 m/s), followed by cfPWVsub (7.98±1.7 m/s), supPWVestim (7.83±1.7 m/s) and sitPWVestim (7.80±1.6 m/s). - We observed significant mean differences only between cfPWV0.8 and all other PWV measures: with cfPWVsub (0.23 m/s, p = 0.001), with sitPWVestim (0.39 m/s, p = 0.001) and with supPWVestim (0.38 m/s, p = 0.002). No significant correlation was found between the mean and the difference for PWV in any comparison. - Association with cardiac damage was highest with cfPWVsub, supPWVestim and sitPWVestim were more closely related to carotid damage, though differences were not significant. - Comparison of PWV - Mean difference - CI - p - cfPMVsub–supPWVestim - 0,16 - −0,06/0,37 - 0,149 - cfPWVsub–sitPWVestim - 0,18 - −0,034/0,39 - 0,098 - cfPWV0.8–supPWVestim - 0,38 - 0,15/0,62 - 0,002 - cfPWV0.8–sitPWVestim - 0,39 - 0,15/0,63 - 0,001 - cfPWV0.8–cfPWVsub - 0,23 - 0,12/0,35 - 0,000 - supPWVestim–sitPWVestim - 0,02 - −0,07/0,12 - 0,635 - cfPWV0.8: direct distance x 0.8-based carotid-femoral PWV. - cfPWVsub: subtracted distance-based carotid-femoral PWV. - sitPWVestim: estimated aortic PWV in sitting position. - supPWVestim: estimated aortic PWV in supine position. Table 3.- Differences between PWV measured by applanation tonometry according to two surface measurements and by brachial oscillometry according to supine ox sitting position. - Conclusions: SC and MG showed similar and acceptable reproducibility. SC and MG were interchangeable only using subtracted distance (cfPWVsub), while direct distance x 0.8 showed significantly higher PWV values. Association to TOD was significant and similar between SC and MG. 
- Open Access
- This is an open access article distributed under the CC BY-NC license.
Cite this article
TY - JOUR AU - Enrique Rodilla AU - Jose Antonio Costa AU - Francisco Perez AU - Carmen Gonzalez AU - Jose Maria Pascual PY - 2017 DA - 2017/12/06 TI - P57 ASSESSMENT OF PULSE WAVE VELOCITY AND ASSOCIATION TO TARGET ORGAN DAMAGE IN TREATMENT-NAïVE HYPERTENSIVE PATIENTS: A COMPARISON OF SPHYGMOCOR AND MOBIL-O-GRAPH JO - Artery Research SP - 69 EP - 70 VL - 20 IS - C SN - 1876-4401 UR - https://doi.org/10.1016/j.artres.2017.10.079 DO - 10.1016/j.artres.2017.10.079 ID - Rodilla2017 ER -