Proceedings of the 6th International Nursing and Health Sciences Symposium (INHSS 2025)

6th International Nursing and Health Sciences Symposium (INHSS 2025)

📍Malang, Indonesia🗓️ 27 November 2025

Comparison of Blood Pressure Measurements Between Aneroid and Digital Sphygmomanometers in Hypertensive Older Adults

Authors
Akhiyan Hadi Susanto1, *, Zakia Zakia1, Kumboyono Kumboyono1
1Department of Nursing, Faculty of Health Sciences, Universitas Brawijaya, Malang, Indonesia
*Corresponding author. Email: susanto.akhiyan@ub.ac.id
Corresponding Author
Akhiyan Hadi Susanto
Available Online 4 September 2026.
DOI
10.2991/978-94-6239-770-5_11How to use a DOI?
Keywords
Aneroid Sphygmomanometer; Blood Pressure Measurement; Digital Sphygmomanometer; Hypertensive Elderly; Measurement Accuracy
Abstract

Blood pressure measurement errors may lead to serious clinical consequences, including misclassification of hypertension due to false-positive or false-negative results. Accurate measurement is therefore essential for effective hypertension management, particularly in older adults. This study aimed to compare blood pressure measurements obtained using aneroid and digital sphygmomanometers in hypertensive older adults. A paired comparative study was conducted among 70 hypertensive older adults aged ≥ 60 years in the working area of Dinoyo Health Center, Malang City, Indonesia. Participants were selected using accidental sampling. Blood pressure was measured using both aneroid and digital sphygmomanometers following standardized procedures. The paired blood pressure measurements obtained using the aneroid and digital sphygmomanometers were compared using the Wilcoxon signed-rank test because the data were not normally distributed. The results showed no statistically significant differences in systolic and diastolic blood pressure measurements between the two devices (p > 0.05). The findings indicate comparable measurement outcomes between the two devices. In conclusion, aneroid and digital sphygmomanometers demonstrated similar performance in measuring blood pressure among hypertensive older adults. However, further studies using more rigorous designs are recommended to confirm the interchangeability of these devices in clinical practice.

Copyright
© 2026 The Author(s)
Open Access
Open Access This chapter is licensed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (http://creativecommons.org/licenses/by-nc/4.0/), which permits any noncommercial use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license and indicate if changes were made.

Download article (PDF)

Volume Title
Proceedings of the 6th International Nursing and Health Sciences Symposium (INHSS 2025)
Series
Advances in Health Sciences Research
Publication Date
4 September 2026
ISBN
978-94-6239-770-5
ISSN
2468-5739
DOI
10.2991/978-94-6239-770-5_11How to use a DOI?
Copyright
© 2026 The Author(s)
Open Access
Open Access This chapter is licensed under the terms of the Creative Commons Attribution-NonCommercial 4.0 International License (http://creativecommons.org/licenses/by-nc/4.0/), which permits any noncommercial use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license and indicate if changes were made.

Cite this article

TY  - CONF
AU  - Akhiyan Hadi Susanto
AU  - Zakia Zakia
AU  - Kumboyono Kumboyono
PY  - 2026
DA  - 2026/09/04
TI  - Comparison of Blood Pressure Measurements Between Aneroid and Digital Sphygmomanometers in Hypertensive Older Adults
BT  - Proceedings of the 6th International Nursing and Health Sciences Symposium (INHSS 2025)
PB  - Atlantis Press
SP  - 99
EP  - 106
SN  - 2468-5739
UR  - https://doi.org/10.2991/978-94-6239-770-5_11
DO  - 10.2991/978-94-6239-770-5_11
ID  - Susanto2026
ER  -